2gig Technologies EDGE Installation Manual page 16

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

Sensor Reports
1 . Highlight Sensor Reports.
2 . Choose Enabled or Disabled.
3 . Tap t to move to the next option.
Sensor Supervised
1 . Highlight Sensor Supervised.
2 . Under Sensor Supervised, choose Enabled or Disabled.
3 . Tap t to move to the next option.
Next Steps
The wireless zone is now programmed. Next, choose one of these options:
➣ To program the next wireless zone, tap Next Zone. Then, repeat the programming steps for the next zone.
➣ To erase all of the programmed settings for the wireless zone, tap Reset Zone.
➣ To go to the list of wireless zones, tap Back to Zones.
➣ Changes are saved instantly, so simply exit the toolbox to start using the new sensor/device.
P
P
– B
-i
Z
anel
rogramming
uilt
n
ones
You can program up to three (3) Built-In Zones per system (two Hard-wired zones and the Panel Glassbreak detector). To get started, navigate to
. Tap Panel Programming, then tap the Built-In Zones option.
the
Installer Toolbox
Selecting a Wired Built-In Zone
1 . On the left side of the Built-In Zone screen, review the list of zones.
2 . Tap one of the available zones to highlight it. A zone is available when it
appears in gray text.
3 . Tap EDIT ZONE.
Sensor Type
1 . Highlight Sensor Type.
2 . Tap
to expand the list.
3 . Select the appropriate sensor type from the list.
For example: for a Door/Window Contact for a Patio Door,
perhaps select 03-Perimeter.
4 . Tap t to move to the next option.
Normal State
1 . Highlight Normal State.
2 . Choose one of these options:
➣ Normally Open (NO): Sends alert signal to the security system
when the sensor's circuit is no longer in the NO state.
➣ Normally Closed (NC): Sends alert signal to the security system
when the sensor's circuit is no longer in the NC state.
End-of-Line Resistor (EOL): Choose when an end- of-line (EOL)
resistor is present.
2GIG EDGE Installation Guide
30
Voice Descriptor
1 . Highlight Voice Descriptor.
2 . Tap Edit Voice Descriptor to reveal the keypad.
3 . Enter the first few letters of the desired word.
4 . Tap the matching word above the keypad.
5 . Repeat the steps above to enter a phrase.
6 . Tap Done.
7 . Review the voice descriptor.
8 . Tap t to move to the next option.
Sensor Chime
1 . Highlight Sensor Chime.
2 . Choose the desired chime from the list. The default setting is Disabled.
Smart Areas Assignment
1 . Highlight Smart Areas Assignment.
2 . Choose a Smart Area (Partition) for the zone.
3 . Tap t to move to the next option.
Transmission Delay
1 . Highlight Transmission Delay.
2 . Choose Enabled or Disabled.
3 . Tap t to move to the next option.
Sensor Reports
1 . Highlight Sensor Reports.
2 . Choose Enabled or Disabled.
3 . Tap t to move to the next option.
Copyright © 2021 Nortek Security & Control LLC
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents