2gig Technologies EDGE Installation Manual page 22

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

P
P
– a
P
anel
rogramming
dvanced
rogramming
You can program a variety of settings for the 2GIG EDGE Panel. To get started, navigate to the Installer Toolbox. Then, tap
Advanced Programming > System Configuration
.
Advanced Programming
Options include:
System Configuration
Timers, Delays & Counts
Panel Configuration
Troubles
Reporting
On the left side of each option's screen are a variety of programming
questions related to how the 2GIG EDGE Panel and different system
components operate.
1 . Highlight a question [Q### - (settings differ based on the question)].
2 . Tap available options to adjust settings.
3 . Tap  to move to the next question, or tap  to return to the previous
menu.
NOTE: Ensure that the settings you program are in compliance with
all national, state, and local regulations.
NOTE: For more in-depth information about the list of questions
available in the Panel Programming menu, see Advanced
Programming,
page
43.
2GIG EDGE Installation Guide
Panel Programming >
42
ADVANCED PROGRAMMING
System Configuration
This section details the Panel Programming questions. A dagger (†) indicates a factory default setting.
default setting for compliance with ANSI/SIA CP-01-2010: Control Panel Standard - Features for False Alarm Reduction
Q101: Change installer code
Defines the unique four-digit code for installers to use when accessing the 2GIG EDGE Panel's Installer Toolbox. See Installer Toolbox,
Choose one of these options:
»
† 1561: This is the factory default setting.
»
Enter a unique code. If you change the Installer Code, be sure to remember it so you can access the system later. The Installer Code
must be unique from the Master User Code and all other user codes.
IMPORTANT: To minimize the risk of unwanted persons circumventing the system, 2GIG alarm dealers and professional installers are
advised to change the system's default Installer Code to a unique one. This helps to prevent unwanted persons from gaining access to
critical programming features of the 2GIG EDGE Security & Smart Home System.
Q102: Security pin code length
Configures the system's pin code length.
Choose one of these options:
»
† 4 Digits: Installer, Master, duress and user codes will be 4 or 6 digits long.
»
6 Digits: Installer, Master, duress and user codes will be 6 digits long.
NOTE: If changing from 4 to 6-digit pin codes, all existing codes will be appended with "11". The default 6-digit Installer pin code is
156111 and Master 111111.
NOTE: When changing from 6 to 4-digit pin codes all pin codes will be truncated, removing the last 2 digits. If this action causes
conflicts, the system will prompt to resolve the conflicts. Conflicts can be resolved by defaulting the user codes or changing the existing
pin codes so that no first four digits of the pin codes are the same.
Q103: Lock installer programming
This feature prevents system takeovers by locking the installer programming features in the System Configuration menu after 48 hours. The 48-hour
lockout timer starts when the installer exits System Configuration mode. To restore access after the 48-hour period, installers must reset the lockout timer
using the backend dealer portal. When this feature is enabled, the following programming features are locked out after 48 hours:
»
Q101: Enter installer code (4 or 6 digits)
»
Q103: Lock installer programming
»
Q104: Lock default programming
Choose one of these options:
»
† Disabled (Full Access): This turns the feature OFF. Installer programming remains unlocked after 48-hours.
»
No Access: This turns the feature ON. The programming features are fully restricted after 48-hours.
»
Limited Access: This turns the feature ON. The programming features are partially restricted after 48-hours.
Q104: Lock default programming
Prevents system takeovers by limiting the installer's ability to restore the 2GIG EDGE Panel's factory-default settings.
Choose one of these options:
»
† Allow Reset of All Defaults: Lets installers restore the factory-default values to the 2GIG EDGE Panel.
»
Allow Limited Reset of Defaults: Lets installers restore some of the factory-default values, with the exception of
above,
installer code (4 or 6 digits)
Q103: Lock installer programming
48 hours after the setting is changed, and the countdown timer starts when you exit the System Configuration menu.
»
Do Not Allow Reset of Defaults: Does not let installers restore the factory default values to the 2GIG EDGE Panel. This setting
starts when you exit the System Configuration menu.
Q105: 2-way voice
Configures the system to automatically turn the 2GIG EDGE Panel's 2-Way Voice feature ON or OFF after the type of alarm you specify. This gives
the 2GIG EDGE Panel's Cellular Radio Module the ability to automatically dial the Central Station and connect with an operator after an alarm
sounds. Once connected with the Central Station, people on the premises can communicate with the operator using the 2GIG EDGE Panel's built-
in speaker and microphone.
Choose one of these options (next page):
A double dagger (‡) indicates a
.
page
Q101: Enter
above,
above. This setting takes effect
Q104: Lock default programming
Copyright © 2021 Nortek Security & Control LLC
43
27.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents