Alarm Programming Instructions
Tip:
1. Select the camera requiring alarm programming.
2. Press Menu.
3. Scroll through the menu selections until Alarm Actions is displayed on the LCD.
Press Zoom or Focus to select.
4. The information for input 1 appears on the LCD. If this is not the correct input number,
use the Tracker Ball to scroll until the correct input number appears. Continue with
step 5.
Note:
5. Enter response camera number in the Cam field (top right of LCD).
6. Move the Tracker Ball right to the Video Action field (second line of LCD). Do one of
the following:
Press View and enter the view number (1-96) to display a Quick View.
Press View and leave the number field blank to display a fixed shot.
Press Pattern and enter the pattern number (1-3) to run a Pattern.
7. Move the Tracker Ball right to the Triggered Output field (lower right of LCD). Enter
the output number. This output must be connected to the camera you picked in step 5.
Note:
8. Do one of the following:
To configure a different alarm input for the same camera: Use the Tracker Ball to
scroll to another input. Repeat Steps 5 through 7.
To configure alarm inputs for a different camera: Press Previous or Next until the
correct camera number appears in the Alarm Camera field (upper left of LCD). Repeat
Steps 4 through 7.
To complete alarm programming: Press Menu to save programming and return to
camera control mode.
4-10
Only the Primary Controller can be used to perform this task.
Press Clear to remove any previously programmed alarm information.
Leave this field blank if you do not want an output to initiate.