Model AD1202
MCS Coax Controller
Installation and Operating Instructions
This manual describes the installation and operating procedures for the AD1202 MCS Coax Pan/Tilt and Lens Controller. The
AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site. Each camera
can be individually controlled from AD1202 front panel switches to provide pan, tilt, lens, preset scene, and auxiliary functions at
the camera site. The AD1202 can also operate as a control follower when used with MCS-compatible AD switchers.

Advertisement

Table of Contents
loading

Summary of Contents for American Dynamics AD1202

  • Page 1 This manual describes the installation and operating procedures for the AD1202 MCS Coax Pan/Tilt and Lens Controller. The AD1202 Controller allows coax control of four color or monochrome cameras via the video line to the camera site. Each camera can be individually controlled from AD1202 front panel switches to provide pan, tilt, lens, preset scene, and auxiliary functions at...
  • Page 2 The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system. Information furnished by SENSORMATIC is believed to be accurate and reliable.
  • Page 3 The installation of this product should be made by qualified service personnel and should conform to all local codes. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVERS (OR BACK) . NO USER-SERVICEABLE PARTS INSIDE.
  • Page 5: Table Of Contents

    DESCRIPTION... 1 FEATURES... 1 INSTALLATION ... 1 CONNECTIONS ... 2 Camera Video Inputs... 2 Looping Video Outputs... 2 Monitor Video Output... 2 EXTERNAL Connector... 3 Power Connection... 4 FRONT PANEL CONTROLS... 5 SETUP ... 6 Factory Reset ... 6 Camera Selection ... 6 Camera Programming ...
  • Page 7: Description

    Receivers. Each camera can be individually selected and controlled from the AD1202 front panel. The selected camera’s video input is displayed via the rear panel Monitor output. Pushbutton control is provided for camera pan/tilt, lens zoom/focus/iris, preset scene, and auxiliary functions.
  • Page 8: Connections

    CONNECTIONS CONNECTIONS All connections to the AD1202 Coax Controller are made on the unit’s rear panel, illustrated in Figure 2. Typical AD1202 connections with other AD units are illustrated in the Typical System Connections section at the end of this manual.
  • Page 9: External Connector

    Alarm Input 1 Alarm Input 2 From the rear of the AD1202, pin 1 is the bottom-right, pin 2 is the top-right, and pin 24 is the top-left of the connector. Use NEC Class 2 wiring only for all EXTERNAL connector pin connections.
  • Page 10: Power Connection

    120VAC, 50/60 Hz ADS1202X - 230VAC, 50/60 Hz There is no power switch on the AD1202 or ADS1202X. Power is applied to the unit when the cord is plugged into the power source. NOTE: THE SOCKET OUTLET SHALL BE LOCATED NEAR THE EQUIPMENT AND SHALL BE READILY ACCESSIBLE.
  • Page 11: Front Panel Controls

    Mode can only activate four momentary auxiliaries. Programming Group PGM - Enters Camera Programming (page 6) to program the AD1202 for specific camera numbers for use with a compatible AD switcher. The illuminated LED above the PGM button indicates camera programming operation.
  • Page 12: Setup

    The AD1202 is factory set for operation with input number 1 set to follow switcher camera 1, input 2 for camera 2, input 3 for camera 3, and input 4 for camera 4. Each AD1202 input can be programmed to follow any of 16 camera numbers.
  • Page 13: Preset Scene Programming

    AD1640/1680 Series Receivers. A suitably equipped camera site Receiver can store 72 preset scenes for subsequent recall. The AD1202 can program and call any of the first four preset scenes (1 - 4). Preset scenes are stored at the respective camera Receiver, not in the AD1202.
  • Page 14: Coax Code Selection

    See Camera Selection, page 6, to set the AD1202 camera selection method. CAMERA SELECTION AS A COAX CONTROLLER When the AD1202 is set as a coax controller, select a camera from the AD1202 front panel by pressing the corresponding Channel Select button for the desired camera input number (1 - 4).
  • Page 15: Calling Preset Scenes

    Calling a Preset Camera Scene A suitably equipped AD Receiver can store a maximum of 72 preset scenes. The AD1202 can call any of the first four preset scenes using the front panel PRESET buttons. See Preset Scene Programming, page 7, to program preset scenes.
  • Page 17: Appendix

    Appendix...
  • Page 18: Built-In Test

    APPENDIX BUILT-IN TEST The AD1202 has a built-in test procedure that provides a verification of AD1202 front panel controls. CAUTION - Due to the presence of non- insulated components with hazardous voltages, the following test procedure should be performed by qualified service personnel only.
  • Page 19: Typical System Connections

    Typical System Connections...
  • Page 20 TYPICAL SYSTEM CONNECTIONS AD1202 with four AD1641U Coax Receivers and Alarms NOTE: AD1641U Receivers shown for illustration. Any AD Receiver with Coax control may be connected in this manner. If using an AD 1645U do not connect pins 23 and 24.
  • Page 21 AD1202 with two AD1641U Coax and two AD1641M Control Code Receivers PAN/TILT CAMERA 2 AD1641U COAX RECEIVER PAN/TILT CAMERA 1 AD1641U COAX RECEIVER ALL INPUTS TERMINATED IN 75 TYPICAL SYSTEM CONNECTION NOTE: AD1641 Series Receivers shown for illustration. Any AD Receiver with Coax or AD Manchester Control Code may be connected in this manner.
  • Page 22 AD1202 with two AD1240 Series P/Ts and two AD1641U Coax Receivers PAN/TILT CAMERA 2 AD1641U COAX RECEIVER PAN/TILT CAMERA 1 AD1641U COAX RECEIVER ALL INPUTS TERMINATED IN 75 TYPICAL SYSTEM CONNECTION NOTE: AD1641 Series Receivers shown for illustration. Any AD Receiver with Coax or AD Manchester Control Code may be connected in this manner.
  • Page 23 TYPICAL SYSTEM CONNECTIONS Two AD1202 Controllers with AD1408A Switcher NOTE: If using an AD1645U do not connect pins 23 and 24 PAN/TILT CAMERA 1 AD1641U COAX RECEIVER TERM 1 2 3 4 HI-Z ADDITIONAL COAX RECEIVERS AD1202 DATA EXTERNAL 120V...
  • Page 25: Index

    Index...
  • Page 27 Video Input Termination ......7 ZOOM Button ........5 AD1202...
  • Page 29: Troubleshooting

    Black horizontal lines through Faulty camera sync or video output picture, or picture not stable Unit is in external mode and the Monitor output of AD1202 is incorrectly used monitor output of the AD1202 is displaying the last camera selected Camera Control Problems...
  • Page 31 Ed Thompson Engineering Manager European Contact: Sensormatic GmbH Am Schimmersfeld 7, 40880 Ratingen, Germany Sensormatic CCTV Systems Division 600 Bradley Hill Road Blauvelt, NY 10913 USA Sensormatic Electronics Corporation (IRL) LTD Melbourn Road, Bishopstown Cork, Ireland MCS Coax Controller ADS1202X...
  • Page 32: Specifications

    AD1202: ADS1202X: 230 VAC, 50/60 Hz, 50 mA Video Signal: AD1202 - EIA RS-170/NTSC Video, 525 lines @ 60 Hz ADS1202X - CCIR/PAL Video, 625 lines @ 50 Hz Video Inputs: Four input BNC's, 1 Vp-p composite video, selectable termination for each input...