15.5.36 Field settings

BRC1H519W+K+S7
Madoka wired remote controller
4P513689-1E – 2020.12
Make indoor unit and remote controller field settings. For an overview of possible
field settings, see
"Indoor unit field
4
settings" [
 71].
Setting procedure
Field settings are composed of the following components:
Modes
Units
Settings
Values
The field settings procedure differs depending on whether you are making settings
for individual indoor units or for groups of indoor units, or for the remote
controller.
Field settings type
Individual indoor units
Groups of indoor units
Remote controller
15
4
settings"  [
  69] and
"Remote controller field
Procedure
Set the field setting type to "Indoor
unit".
Define a mode. In the field settings
table, find this number between
brackets in the Mode column.
Define the unit to which the setting
will apply by setting a unit number.
Define the setting by tapping the right
tile in the app. In the field settings
table, find settings in the SW column.
Define a value for that setting.
Set the field setting type to "Indoor
unit".
Define a mode. In the field settings
table, find this number NOT between
brackets in the Mode column.
Do NOT set a unit number (the
settings will apply to all units in the
group).
Define the setting by tapping the right
tile in the app. In the field settings
table, find settings in the SW column.
Define a value for that setting.
Set the field setting type to "Remote
controller".
Define a mode.
Define the setting by tapping the right
tile in the app. In the field settings
table, find settings in the SW column.
Define a value for that setting.