INFORMATION
The lower the outdoor air temperature, the lower the heating capacity. If the
system's heating capacity is insufficient, it is recommended to include another
heating appliance into the setup (if you use a combustion appliance, ventilate the
room regularly. Also, do not use the heating appliance in places where it is
exposed to the airflow of the indoor unit).
The indoor unit is of the hot air circulation type. As a result, after operation start,
it takes the indoor unit some time to warm up the room.
The indoor unit fan will automatically operate until the indoor temperature of the
system rises to a certain level.
When hot air stays under the ceiling and your feet feel cold, it is recommended to
include a circulator into the setup.
NOTICE
To prevent water leakage or system failure, do NOT turn off the system immediately
after indoor unit operation. Before turning off the system, wait until the drain pump
finishes discharging any water remaining in the indoor unit (approximately 1 minute).
INFORMATION
To ensure a smooth start, do not turn off the system while it is operating.
INFORMATION
In case of indoor unit setpoint logic, the system cannot run in Auto operation mode.
Therefore, to allow for Auto operation mode, go for remote controller setpoint logic.
For more information, see the Madoka Assistant app and
The Auto operation mode logic depends on the set setpoint logic (Madoka
Assistant app setting).
Single setpoint
C2
+ C1
SP
+ C1
C2
DIFF Minimum setpoint differential between the Heating and
+C1 Changeover setpoint (with guard timer)
C2 Forced changeover setpoint
0.5°C~2°C Field settable temperature intervals between setpoints
0.5°C
~
2°C
0.5°C
2°C
~
0.5°C
~
2°C
0.5°C
2°C
~
Cooling setpoint
Heating setpoint
the Cooling setpoint
4
"Setpoint
logic" [
 108].
Dual setpoint
C2
0.5°C
~
2°C
+ C1
0.5°C
2°C
~
SP
DIFF
SP
0.5°C
~
2°C
+ C1
0.5°C
2°C
~
C2
BRC1H519W+K+S7
Madoka wired remote controller
4P513689-1E – 2020.12