Example 2
Force fan ON
About Force fan ON
To force fan operation
BRC1H519W+K+S7
Madoka wired remote controller
4P513689-1E – 2020.12
1 You open the window.
Result: The unit stops immediately. It is not possible to turn the unit on or off
with the ON/OFF button, the Setback functionality does not work, and the
delay timer does not start counting.
2 You remove the key card.
Result: The delay timer starts counting.
3 You close the window again.
Result: There is no change in state. It is as if you never opened the window
(Setback will work if enabled).
IF the delay timer HAS expired before closing the window, the reset
timer will have started counting. Closing the window has no influence
on the reset timer.
IF the delay timer HAS NOT expired before closing the window, it will
expire immediately and the reset timer will start counting. When the
reset timer expires, the previous state is updated to the "Default Reset
Setting" state.
4 You insert the key card again.
Result:
IF the reset timer HAS NOT expired before inserting the key card, the
unit returns to the state before the window was opened (last "on"
state);
IF the reset timer HAS expired before inserting the key card, the unit
goes to the "Default Reset Setting" state.
Force fan ON allows you to force fan operation of individual indoor units. In this
way, you can check which indoor unit number was assigned to which indoor unit.
Prerequisite: You are in the installer menu.
1 Navigate to the Force Fan ON menu.
2 Select an indoor unit number.
3 Select
and press
to force fan operation.