Inspection Activities; Preventive Inspection Of All Cables, Dresspack - ABB DressPack IRB 6620LX Product Manual

Hide thumbs Also See for DressPack IRB 6620LX:
Table of Contents

Advertisement

3 Maintenance

3.3.1 Preventive inspection of all cables, DressPack

3.3 Inspection activities

3.3.1 Preventive inspection of all cables, DressPack
Cables in the DressPack system
There are many different cables used in the DressPack system. The different cables
used are listed in Spare parts section.
The inspection activities described below are a general description, and does not
refer to any specific cable.
Required equipment
Equipment
Standard Toolkit,
DressPack/SpotPack
Inspection
The procedure below details how to inspect all cables included in the SpotPack
system.
This instruction applies to:
1
2
3
4
5
Continues on next page
86
Art. no.
3HAC17290-7
DressPack upper arm and cables and hoses contained within
DressPack lower arm and cables and hoses contained within
DressPack lower/upper arm and cables and hose contained within
DressPack floor and cables and hoses contained within.
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
Make sure that the unit is clean and not
overly contaminated.
Make sure that all bolts are fastened.
Make sure that all connections are fastened.
Make sure that all hose connections are
fastened and that there are no leaks.
© Copyright 2016-2017 ABB. All rights reserved.
Note
The contents are defined in section
DressPack/SpotPack on page
Note
Recommended tightening torques are
specified in section
page
107.
Re-tighten if necessary.
Re-tighten if necessary.
Product manual - DressPack/SpotPack IRB 6620LX
3HAC055327-001 Revision: A
Toolkits,
111.
Screw joints on

Advertisement