54
NetWare 4.2 – Boot Controller
This procedure is for installing a SmartRAID VI controller as the boot
device in a NetWare 4.2 server.
1.
Download the NETWARE.ZIP file from the DPT Technical
Support web site. Extract NW42.ZIP to a floppy disk.
2.
Install the SmartRAID VI controller as the primary controller and
attach the disk drives or storage subsystem.
Ensure that you are using a CD-ROM that is not attached to the
DPT controller.
3.
Create a directory on the C: drive named NWUPDATE.
4.
Insert the diskette that you created from the download file into
the floppy disk drive.
5.
Copy A:\NW42 to C:\NWUPDATE.
6.
Start the NetWare installation program from the CD-ROM. Use
the Custom Installation option.
7.
On the Server Drivers - Summary menu, highlight Disk and
CDROM Drivers and press Enter.
8.
Highlight Select an Additional Driver and press Enter.
Select I2OPCI.NLM and press Enter.
Enter the slot number.
Highlight Save Parameters and Continue. Press Enter.
9.
Answer Yes when prompted to select an additional driver.
10. Select BKSTROSM.HAM and press Enter.
Enter the slot number.
Highlight Save Parameters and Continue. Press Enter.
11. Answer No when prompted to select an additional driver.
12. Highlight Continue Installation and press Enter.
13. Verify that BKSTROSM.HAM is listed after I2OPCI.NLM in your
STARTUP.NCF file.
Continue with the NetWare 4.2 installation according to the Novell
documentation.