Setting The Boot Controller; Creating An Array; Creating An Array With The Acu - Adaptec ICP5045BL User Manual

Adaptec icp5045bl serial controllers: user guide
Hide thumbs Also See for ICP5045BL:
Table of Contents

Advertisement

Setting the Boot Controller

Note:
If your system won't contain more than one bootable controller, skip to the next section,
Creating an
Array.
Your ICP RAID controller supports bootable disk drives and bootable arrays. To enable your
system to boot from either a disk drive or an array connected to your controller:
Enter the system setup.
1
Navigate to the drive boot sequence.
2
Move the boot controller to the top of the list.
3
For more information, refer to your computer documentation.

Creating an Array

This section explains how to create an array.
A RAID 5 array is created in the examples shown in this section because RAID 5 provides the
most security and best performance with a minimum of three disk drives. However, you can
choose to create an array with a different RAID level; you can also change array level later, after
the operating system is installed.
You can create an array using any of these tools:
Array Configuration Utility (ACU)—BIOS-based menus and keyboard navigation (see
the following section).
ICP Storage Manager—Graphical software application (running from a bootable RAID
installation CD) that you can navigate with your mouse (see
ARCCONF—Command line utility, refer to the Command Line Interface (CLI) User's
Guide.
You can use either tool, but the ACU utility is the quicker and easier tool for this task.
Note:
ICP recommends that you not combine SAS and SATA disk drives within the same array.
ICP Storage Manager generates a warning if you try to create a logical drive using a
combination of SAS and SATA disk drives. See

Creating an Array with the ACU

The ACU is menu-based and instructions for completing tasks appear on-screen. Menus can
be navigated using the arrows, Enter, Esc, and other keys on your keyboard.
To create a RAID 5 array:
Power on your computer. When prompted, press Ctrl+A to enter the ICP RAID
1
Configuration utility.
Note:
During boot up, if your system has insufficient memory the following message will
display. "ICP RAID Configuration Utility will load after, system initialization. Please wait... Or
press <Enter> Key to attempt loading the utility forcibly [Generally, not recommended]"
If you have more than one controller of the same model or family in your computer, select
2
your controller, then press Enter.
Select Array Configuration Utility, then press Enter.
3
Chapter 6: Creating a Bootable Array
page
61).
page 68
for more information.
43

Advertisement

Table of Contents
loading

Table of Contents