Output Buffer, Communication Block From Plc To Pfea113 - ABB PFEA 113 User Manual

Measurement & analytics, web tension systems with tension electronics
Table of Contents

Advertisement

3.13.5.5 Output Buffer, Communication Block from PLC to PFEA113

Data
Boolean out
3BSE029382R0101 Rev C
Section 3.13.5 Handling of Measurement Data through Profibus
Bit No. 0: Flash memory error
Bit No. 1: EEPROM memory error
Bit No. 2: Supply error
Bit No. 3: Load cell excitation error
Bit No. 4: Synchronization problem
Byte No. 14
Bit No. 0: Level detector 1 is active
Bit No. 1: Level detector 2 is active
Bit No. 2: Level detector 3 is active
Bit No. 3: Level detector 4 is active
This section specifies Boolean values in the output buffer communication block.
Byte No.
7
01
No. 7
02
Bit No. 0: Zero Set. Zero set is performed when the bit is changed from "0" to "1".
Zero set of Roll 1 or
Zero set of all load cells if Segmented roll is selected.
Bit No. 1: Zero Set. Zero set is performed when the bit is changed from "0" to "1".
Zero set of Roll 2
Bit No. 2: Gain Scheduling.
Wrap gain parameter 1 is used if the bit is set to "0"
Wrap gain parameter 2 is used if the bit is set to "1"
Tension Electronics PFEA113, User Manual
Bit No.
6
5
4
No. 6
No. 5
No. 4
Spare for future use
3
2
1
No. 3
No. 2
No. 1
0
No. 0
3-47