Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning

3.13.5.1 Miscellaneous Menu

1. Profibus Scaling: Two rolls selected in SystemDefinition
From DI
WebTension
Miscellaneous
Menu
> 5 s
FastSetUp
Presentation-
Menu
ServiceMenu
System-
Definition
ObjectType
SetNominal-
Load
ZeroSet
This menu is not
shown if One roll
SetWrapGain
is selected in
SystemDefinition
AO 1 - AO 6
DO 1 - DO 4
AI 1 - AI 2
DI
Miscellaneous
Menu
ServiceMenu
3-42
The scaling of analog outputs does not affect the measurement values transferred through
Profibus.
If zero set has been performed, the zero set values are transferred through Profibus.
Scaling of Profibus measurement values, see
Each measurement value has 16 bit, 2-complement representation (Integer 16).
Use this menu to scale Profibus measurement values.
Profibus On/Off
ZZ
ProfibusAddress
ZZZ
To
(Only shown if
Profibus is On)
MeasuringRange
Roll 1
(Only shown if
Profibus is On)
MeasuringRange
Roll 2
(Only shown if
Profibus is On)
SetFactory
Default
Figure 3-25. Profibus Scaling, One Roll or Two Rolls
Section
3.13.5.2.
Profibus On/Off
[ZZ]
ProfibusAddress
[ZZZ]
MeasuringRange
XXX.XXX N
LoadDivision
XXX.XXX N
MeasuringRange
XXX.XXX N
LoadDivision
XXX.XXX N
AreYouSure
3BSE029382R0101 Rev C
MeasuringRange
[XXX.XXX] N
MeasuringRange
[XXX.XXX] N
ActionDone
(shown for 1 s.)