ABB PFEA 113 User Manual page 64

Measurement & analytics, web tension systems with tension electronics
Table of Contents

Advertisement

Tension Electronics PFEA113, User Manual
Chapter 3 Commissioning
WebTension
> 5 s
FastSetUp
Presentation-
Menu
System-
Definition
ObjectType
SetNominal-
Load
ZeroSet
SetWrapGain
AO 1 - AO 6
DO 1 - DO 4
AI 1 - AI 2
DI
Miscellaneous
Menu
ServiceMenu
3-32
DO 1
1
To DO 2
DefineFunction is the last menu if "Off" or "Status" is selected
Web Tension
High level
Low level
DefineFunction
ZZ
ConnectSignals
ZZ
HighLevel
XXXXXX.X N
LowLevel
XXXXXX.X N
Hysteresis
XXXXXX.X N
High and Low Level detector
"Off"
"On"
"On"
"Off"
Low
High
High
DefineFunction
1
[ZZ]
ConnectSignals
[ZZ]
HighLevel
[XXXXXX.X] N
LowLevel
[XXXXXX.X] N
Hysteresis
[XXXXXX.X] N
Hysteresis
Time
"Off"
"Off"
"On"
High
Low
Low
3BSE029382R0101 Rev C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents