3.12.3.3 Setting Object Types for Segmented Roll
WebTension
> 5 s
FastSetUp
Presentation-
Menu
System-
Definition
ObjectType
SetNominal-
Load
ZeroSet
SetWrapGain
AO 1 - AO 6
DO 1 - DO 4
AI 1 - AI 2
DI
Miscellaneous
Menu
ServiceMenu
3BSE029382R0101 Rev C
Object type SegmentedRoll can be used for up to 12 load cells that are connected to one, two or
three Tension Electronics PFEA113.
Each PFEA113 must be set up for:
•
one input (load cell connected to A)
•
two inputs (load cells connected to A and B)
•
three inputs (load cells connected to A, B and C) or
•
four inputs (load cells connected to A, B, C and D)
Setting Object Types for Segmented Roll
ObjectType
SetObject
ZZ
To
SetNominalLoad
Figure 3-8. Setting Object Types for Segmented Roll
Use up and down keys to select type of object
•
OneInput
•
TwoInputs
•
ThreeInputs or
•
FourInputs
Segmented Roll Scale Factor (SRSF) is used to compensate the total measured tension and
present an estimate of total tension when not all rolls are supported by load cells in a segmented
roll application. For calculations of SRSF, refer to.
Factor
(SRSF).
Segmented Roll (three or four load cells connected to one PFEA113)
B
C
A
Three inputs
Figure 3-9. Segmented Roll Connected to One PFEA113
Tension Electronics PFEA113, User Manual
AreYouSure
[ZZ] from list
Appendix A.3.1 Segmented Roll Scale
A
PFEA113
Input
A
B
C
D
Section 3.12.3 Setting Object Type
SetObject
[ZZ]
.
B
C
D
Four inputs
PFEA113
Input
A
B
C
D
3-19