ABB PFEA 113 User Manual page 86

Measurement & analytics, web tension systems with tension electronics
Table of Contents

Advertisement

Tension Electronics PFEA113, User Manual
Chapter 4 Operation
4-4
Examples of measuring values displayed:
Example 1:
Selected unit [N], Load cell nominal load 100 kN, Measured value 987654 N.
Value presented on display: 987600 N.
Example 2:
Selected unit [kN], Load cell nominal load 100 kN, Measured value 987654 N.
Value presented on display: 987.6 kN.
Examples of measuring values displayed together with the Set Decimals function:
Example 1:
Selected unit [pli], Load cell nominal load 1 kN, Measured value 46.5987 pli.
Set Decimals = 2
Value presented on display: 46.60 pli.
Example 2:
Selected unit [pli], Load cell nominal load 1 kN, Measured value 46.5987 pli.
Set Decimals = 0
Value presented on display: 47 pli.
3BSE029382R0101 Rev C