Tension Electronics PFEA113, User Manual
Chapter 6 Fault-tracing
6.8.3 Changing to Single Side Measurement If One Load Cell Is Faulty
6-8
If one load cell is faulty it is possible to change from Standard Roll to Single Side Measurement.
Depending on which load cell that is faulty, do the following:
For load cell connections, please refer to cable diagrams in Appendix B, C, D, E, F or G for the
load cell type used in the installation.
Load cell A or C is faulty:
Disconnect the faulty load cell from the Tension Electronics.
Connect a shorting wire for the load cell excitation circuit:
•
If load cell A is disconnected:
a.
Connect a shorting wire between X2:1 and X2:2.
•
If load cell C is disconnected:
b.
Connect a shorting wire between X2:5 and X2:6.
Load cell B or D is faulty:
Disconnect the faulty load cell from the Tension Electronics.
Connect a shorting wire for the load cell excitation circuit:
•
If load cell B is disconnected:
–
Connect a shorting wire between X2:3 and X2:4
•
If load cell D is disconnected:
–
Connect a shorting wire between X2:7 and X2:8
After having changed the load cell connections, one parameter setting in the Tension Electronics
must be changed.
•
If load cell A or B is disconnected:
–
Change Roll 1 from StandardRoll to SingleSide.
•
If load cell C or D is disconnected:
–
Change Roll 2 from StandardRoll to SingleSide.
Changing from StandardRoll to SingleSide, see
Standard Roll to Single Side
Section 6.8.3.1 Menus for Changing from
Measurement.
3BSE029382R0101 Rev C