DX4010i/DX4010 DB9 Connector

The DB9 pins are configured as shown in Table 14
and Figure 44 .
DB9 Pin Number
1
2
3
4
5
6
7
8
9

Table 14: DB9 Pin Configuration

1
2
6

Figure 44: DB9 Connector Layout

21.0

Network Interface Module (DX4020)

Firmware revision 2.10 or greater is required
for network communication.
21.1

DX4020 Overview

The DX4020 Network Interface Module (NIM)
provides bi-directional communication over an
Ethernet network. It can also be used for remote
programming sessions with RPS (Remote
Programming Software).
21.2

DX4020 Addressing

Set the DIP Switch address to 134 when using the
DX4020 for network communication.
Network Communication DIP Switch Setting
Example:
Module Address 134
OPEN
1 2 3 4 5 6 7 8
DX4020 Mounting Locations

Figure 45: Network Communication DIP Switch Setting

Page 28
P/N: 4998152533-02
PART II: SYSTEM INSTALLATION AND SETUP
Pin Configuration
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
3
4
5
7
8
9
= Switch OPEN (Up)
=
= Switch CLOSED (Down)
=
Copyright  2007 Bosch Security Systems, Inc.
21.3

DX4020 Installation

Failure to follow the mounting instructions in
this document can result in damage to the
module.
The DX4020 contains static-sensitive
components and must be handled with care.
Follow anti-static procedures when handling
this module.
Mount the DX4020 to the back wall of the control
panel's enclosure. See Figure 46 .
DX4020 Mounting Locations
PO4
PO3
PO2
INSTALLER

Figure 46: DX4020 Mounting Locations

DX4020 Mounting Locations
DS7200V2-UK Installer's Guide