Control Panel Events And Reporting Formats; Table 47: Control Panel Events And Reporting Formats - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

63.0

Control Panel Events and Reporting Formats

The following table includes each control panel event, the description for each event as it appears in the control panel log, the
reports sent for each event, the zone types linked to the event, and the RPS Event Alert Group number. The RPS Event Group
numbers also correspond with the Personal Dialing Format Event Group numbers. See Personal Dialing Format Configuration
on page 106 for more information.
The last column, Status Reports, indicates System Status events. An "R" indicates that reports for the event follow the System
Status routing. An "S" indicates that the event follows the System Status Swinger Count. System reports do not include an
Area number; they use the account number for Area 1.
If the control panel is configured for network communication, reports are sent using the Contact ID format.
The event numbers shown in the following table are the same numbers that show up on a pager for each corresponding
report.
Event as shown
Event #
SIA Report
in Panel Log
01
AC Fail
AC Trouble
02
AC Restore
AC Restoral
03
Alarm,Tamper
Tamper Alarm ri {area} TA {loop}
04*
Alarm,Emergency Emergency
Alarm
05
Alarm,Panic
Panic Alarm
06
Alarm,Invisible
Holdup Alarm
07
Alarm,24-hr Burg Burglary Alarm ri {area} BA {loop}
08
Alarm,Cntrl,Dly
Burglary Alarm ri {area} BA {loop}
09
Alarm,Cntrl
Burglary Alarm ri {area} BA {loop}
10
Cross,Tamper
Burglary Alarm
Cross Zone
11
Cross,Emergency Burglary Alarm
Cross Zone
12
Cross,Panic
Burglary Alarm
Cross Zone
13
Cross,Invisible
Burglary Alarm
Cross Zone
14
Cross,24hr Burg
Burglary Alarm
Cross Zone
15
Cross,Cntrl,Dly
Burglary Alarm
Cross Zone
16
Cross,Cntrl
Burglary Alarm
Cross Zone
* Help Function Keys report as Zones 100, 101, and 102. The [Q] button on a keyfob reports as User Number +200.
Page 124
P/N: 4998152533-02
PART V: REFRENCE MATERIALS
SIA Report Data Contact ID Report
AT
301 AC Loss
AR
301 AC Loss
ri {area} QA {loop} 101 Personal
Emergency
ri {area} PA {loop}
ri {area} HA {loop} 120 Panic
ri {area} BM {loop} 137 Tamper
ri {area} BM {loop} 101 Personal
Emergency
ri {area} BM {loop} 120 Panic
ri {area} BM {loop} 120 Panic
ri {area} BM {loop} 133 24 Hr Safe
ri {area} BM {loop} 134 Entry/Exit
ri {area} BM {loop} 130 Burglary

Table 47: Control Panel Events and Reporting Formats

Copyright  2007 Bosch Security Systems, Inc.
Zone Types
Event Description
Linked to Event
AC Power to panel
interrupted.
AC Power to panel
restored.
Alarm, Tamper Zone
4-Tamper
Type.
Alarm, Emergency
5- Emergency
Zone Type or ABC
Emergency Key
key programmed for
emergency response.
[Q] button.
Alarm, Panic-Visible
6- Visible Panic
Emergency Key
Alarm, Panic- Invisible
7-Invisible Panic
Zone Type or ABC
Emergency Key
key programmed for
panic response.
Alarm, Burglary Zone
8- Burglary
Type.
Alarm, Delay 1 or
11- Delay 1
Delay 2 Zone Type.
Alarm, Keyswitch or
10- Keyswitch
Follower or Instant
Alarm, Tamper Zone
4-Tamper
Type with Cross Zone
Option selected.
Alarm, Emergency
Zone Type with Cross
Zone Option selected.
Alarm, Panic-Visible
Zone Type with Cross
Zone Option selected.
Alarm, Panic- Invisible
Zone Type with Cross
Zone Option selected.
Alarm, Burglary Zone
Type with Cross Zone
Option selected
Alarm, Delay 1 or
Delay 2 Zone Type
12- Delay 2
with Cross Zone
Option selected.
Alarm, Follower, or
Instant Zone Types
with Cross Zone
Option selected.
RPS Event
Status
Group
Reports
12
R
12
R
3
3
3
3
3
3
3
3
3
3
3
3
3
3
DS7200V2-UK Installer's Guide
S
S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7220v2Ds7240v2

Table of Contents