Table 33: Output Mode Options - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

Mode (Steady, Pulse, One Shot), Output ##
• Address: See Table 31
• Default: See Table 31
• Selections: 0-13 (see Table 33 )
There are two types of outputs: state-driven outputs and event-driven outputs. State-driven outputs follow the state of a
condition, either on or off. For example, a state-driven output is Type 0|1 Armed. The output is active when the control panel is
armed and inactive when the control panel is disarmed.
Event-driven outputs follow events when they occur. These events have no On or Off state. For example, an event-driven
output is Type 0|13 Ack Received. When the key is pressed, the output is activated.
The following table describes the mode operation for both on-board and off-board outputs.
Mode
Mode Type
Output
Type
1
Steady
State
Event
2
Latch
State
Event
3
Toggle
State
Event
4
Pulse
State
Event
5
One-Shot
State
Event
6
One-Shot
State
with Re-
Trigger
Event
7
One-Shot
State
with Reset
Event
8
Steady,
State
Reversed
Event
Logic Normal
9
Latch,
State
Reversed
Event
Logic Normal
10
Pulse,
State
Reversed
Event
Logic Normal
11
One-Shot,
State
Reversed
Logic Normal
Event
12
One-Shot
State
with Re-
Trigger,
Event
Reversed
Logic Normal
13
One-Shot
State
with Reset,
Reversed
Event
Logic Normal
Page 92
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
Output turns on when the condition is active and turns off when the condition is inactive.
Output turns on when the event occurs. [System Reset] turns the output off.
Output turns on when the condition is active and remains on until [System Reset] is pressed.
Output turns on when the event occurs and remains on until [System Reset] is pressed.
When the condition goes from inactive to active, the output changes state. The condition going from active to
inactive has no effect.
Whenever the event occurs, the output changes state.
When the condition is active, the output pulses. When the condition is inactive, the output is off.
When the event occurs, the output pulses. The output remains pulsing until [System Reset] is pressed.
When the condition changes from inactive to active, the output turns on. The output turns off at the end of the
One-Shot time. Once the output is on, any changes in the condition are ignored.
When the event occurs, the output turns on and remains on for the One-Shot time. When the output is on, a
second event does not affect the output.
When the condition changes from inactive to active, the output turns on and remains on for the One-Shot time. If
the condition goes inactive and active again, the One-Shot time is restarted and the output remains on.
When the event occurs, the output turns on and remains on for the One-Shot time. If a new event occurs when the
output is on, the One-Shot time is restarted and the output remains on.
When the condition changes from inactive to active, the output turns on and remains on for the One-Shot time. If
the condition goes inactive, the output is turned off early.
When the event occurs, the output turns on and remains on for the One-Shot time. [System Reset] turns the
output off early.
Output turns on when the condition is inactive and turns off when the condition is active.
Output turns off when the event occurs. [System Reset] turns the output on.
Output turns off when the condition is active and remains off until [System Reset] is pressed.
Output turns off when the event occurs and remains off until [System Reset] is pressed.
When the condition is active, the output pulses. When the condition is inactive, the output is on.
When the event occurs, the output pulses. The output continues pulsing until [System Reset] is pressed, then
turns on.
When the condition changes from inactive to active, the output turns off. The output turns on at the end of the
One-Shot time. Once the output is off, any changes in the condition are ignored.
When the event occurs, the output turns off and remains off for the One-Shot time. A second event does not affect
the output.
When the condition changes from inactive to active, the output turns off and remains off for the One-Shot time. If
the condition goes inactive and active again, the One-Shot time is restarted and the output remains off.
When the event occurs, the output turns off and remains off for the One-Shot time. If a new event occurs, the One-
Shot time is restarted and the output remains off.
When the condition changes from inactive to active, the output turns off and remains off for the One-Shot time. If
the condition goes inactive, the output is turned on early.
When the event occurs, the output turns off and remains off for the One-Shot time. [System Reset] turns the
output on early.

Table 33: Output Mode Options

Copyright  2007 Bosch Security Systems, Inc.
Operational Description
DS7200V2-UK Installer's Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7220v2Ds7240v2

Table of Contents