43.0

Global Zone Configuration

Zone Response Options (for all zones)
• Address: 1027
• Default: 0
• Selections: 0-3
Zone Response Options
No Options Selected
Enable Smart Swinger
Unverified Events Send Trouble Reports
Reserved
Reserved
• Smart Swinger: If enabled, this option allows zones that were Swinger Shunted to report new alarm events if they are
faulted when Bell Time is running. The ARC receives alarm reports from zones that previously reported that they were
Swinger Shunted. When Bell Time is running, the Swinger Count applies to these zones. They only send reports until Bell
Time expires or until the swinger count is reached again at which time they Swinger Shunt again. If these bypassed zones
are faulted when Bell Time is not running, they remain Swinger Shunted and do not send reports.
• Unverified Events Send Trouble Reports: If this option is enabled, Fire Alarm with Verification zones that have single,
unverified events generate an Unverified Event report. Zones with the Cross Zone option enabled that have a single pulse
generate an Unverified Event report.
Bypass/Force Arm Report Routing
• Address: 1028
• Default: 0 (No Reports, no Events to Log/Printer)
• Selections:
− 0 = No Reports, no Events to Log/Printer
− 1 = Reports to Destination 1, Events to Log/Printer
− 2 = Reports to Destination 2, Events to Log/Printer
− 3 = Reports to Destinations 1 & 2, Events to Log/Printer
− 4 = Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
− 5 = No Reports, Events to Log/Printer
This parameter sets the routing for Bypass and Forced reports. See Communication Failure (Comm Fail) on page 13 for a
description of the Comm Fail event, and Communication Attempt Tables on page 121 for dialing sequences .
To enable reporting at the Global Reporting Options prompt (see page 47), at least one phone number
(or IP address) must be entered for one routing destination (see page 42).
DS7200V2-UK Installer's Guide
0
Copyright  2007 Bosch Security Systems, Inc.
Enter This Data Digit to Select Options
1
2
3
4
5
6
7