Location ##, Zone Function
• Address: See Table 27
• Default: See Table 27
• Selections: 0-15 (see Table 28 for Zone Function Types)
The zone function determines how the system responds to faults on the sensor loop assigned to the location.
• 24-hour Zone: 24-hour zones are always on and cannot be turned off by the user.
• Controlled Zone: Controlled zones are turned on and off when the user turns the system on (armed) and off (disarmed).
See Table 28 for Zone Function type selections.
Page 76
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
Selection
Default Zone Function Type
0
1
2
24-hour Fire with Alarm Verification
3
24-hour Control Input
4
5
24-hour Emergency
6
24-hour Visible Panic
7
24-hour Invisible Panic
8
9
Controlled Follower (Perimeter)
10
Controlled Keyswitch
11
Controlled Entry/Exit Delay 1
12
Controlled Entry/Exit Delay 2
13
Controlled Follower
14
Controlled Instant
15
Controlled Instant (Perimeter)

Table 28: Default Zone Function Type Selections

Copyright  2007 Bosch Security Systems, Inc.
Disabled
24-hour Fire
24-hour Tamper
24-hour Burglary
DS7200V2-UK Installer's Guide