Digit
Digit
Function Type
1
2
2
2
'Panic' on RF Fob, Bell
Time, PIN resets
2
3
[1]+[3] keys
2
4
[4]+[6] keys
2
5
[7]+[9] keys
2
6
3 Unsuccessful Dialing
Attempts.
2
7
Communication Fail
Event. Successful
communication clears.
2
8
Panel Off Hook
2
9
Ring Detect
2
10
Voice Request
2
11
Follow Keypad Sounder
2
12
Chime
2
13
Ready to Arm (No zones
faulted)
2
14
Exit Error/Bad Set
2
15
Mains 60 Hz
3
0
Ground Start
3
1
Follow Zone Function 1
To
3
15
Follow Zone Function 15
4
0
Change Outputs
4
1
Alarm Zone Function 1
To
4
15
Alarm Zone Function 15
5
0
Change Outputs
5
1
Trouble Zone Function 1
To
5
15
Trouble Zone Function
15
6
0
Change Outputs
6
1
Follow PIN 1
To
6
15
Follow PIN 15
7
0
Follow PIN 16
To
7
15
Follow PIN 31
Page 90
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
Activates when Arm Key (locked icon) and Disarm Key (unlocked icon) on RF Keyfob are pressed at the
same time, or when the [Q] button is pressed and it is set to Duress. Steady and Pulse modes follow bell
time. PIN resets.
Activates when appropriate keys are pressed. [System Reset] resets if no alarm response is assigned.
These output types are event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page 92 for
more information.
Activates after 3 unsuccessful dialing attempts. Resets with first successful call or [System Reset].
Activates after Communication Fail Event. Resets with any successful communication or [System Reset].
Activates when the panel takes the phone line off hook for a dialing attempt. Resets when the control
panel finishes with the phone line and goes on hook.
Activates when the control panel detects a ring on the phone line. Resets when ringing stops.
For use with an optional Voice Verification Module. The output activates for 2 seconds when the control
panel receives an acknowledgement of an alarm report from a zone with the Voice Verification option
enabled. Mode and Time parameters do not apply.
Available for on-board outputs only. Output follows keypad sounderMode and Time parameters do not
apply.
Activates per Chime Feature configuration. Follows keypad sounder per Chime Tone configuration.
Output is activated (on) when: (1) control panel is disarmed & no zones are faulted (2) control panel is
armed & no zones are faulted (3) control panel is armed & any zone is faulted. Output is deactivated (off)
when panel is disarmed & any zone is faulted. Output is deactivated even if the zone became faulted
when panel was armed.
Activates if zone is faulted at the end of Exit Delay or if a Bad Set condition occurs. Resets when the
system is disarmed.
Activates on 60 Hz. Deactivates on 50 Hz.
Activates for approximately 0.5 seconds at the start of any dialing attempt. Use to bring up dial tone in
ground start phone systems.
These 15 output functions activate for any fault on any zone assigned to the specified zone function.
Activated/deactivated by Change Outputs function ([#][5][4]).
These 15 output functions activate for alarms on any zone assigned to the specified zone function and the
area(s) the output is assigned to. They reset when none of the zones assigned to the specified zone
function are in alarm.
Activated/deactivated by Change Outputs function ([#][5][4]).
These 15 output functions activate for troubles on any zone assigned to the specified zone function. They
reset when none of the zones assigned to the specified zone function are in trouble.
Activated/deactivated by Change Outputs function ([#][5][4]).
These output functions activate when the specified PIN is entered.
Output Function Type 7, 12 follows User 28, which can be programmed as the Guard Code User. See
Guard Code Options on page 71 for more information.
These output types are event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page 92 for
more information.
PIN area assignments are ignored when these output functions are selected.
Table 32: Output Function Types (continued)
Copyright  2007 Bosch Security Systems, Inc.
Description
DS7200V2-UK Installer's Guide