9.2

Interface Description

9.2.1

Terminals Internal Description

Terminal
18 VAC
+BATTERY
–BATTERY
OC +
OC2OC1
+12V
GND
R
B
G
Y
Z1-Z8
COM
TIP
TIP1
RING1
RING
9.2.2

Connector Interface Description

Connection Description
P3
Connector
+5V RFIN
GND
P7/OC3
Connector
P8
Connector
Bosch Sicherheitssysteme GmbH
Description
These two terminals are the plug-on type and are the terminal points for the
transformer. To ensure correct operation, the voltage of the transformer must
be 18 VAC to 22VAC at 1.3 A (minimum)
The + Battery terminal connects to the Red positive lead of the battery and the
– Battery terminal connects to the black negative lead of the battery. The
battery should be a 12 VDC sealed lead-acid rechargeable type with a 7 AH
capacity.
The group of terminals provides 2 programmable open collector outputs; the
Maximum rated current is 500 mA for each OC output, with overload and short
circuit protection function.
Independent Power output, +12 V is the positive polarity and GND is negative
polarity.Output voltage: 13.5 VDC +3%/-5% (at AC power), 10 VDC ~ 13.7 VDC
(only battery power) , the Maximum rated current is 500 mA, with overload
and short circuit protection function.
The group of terminals is OPTION bus interface terminals; connect with the
external option bus module such as IUI-AMAX-LED/LCD keypad, DX3010
module. R is power + and B is power -, G is data out and Y is data in. R and B
can be regarded as another independent power output. Output voltage: 13.5
VDC +3%/-5% (at AC power), 10 VDC - 13.7 VDC (only battery power), the
Maximum rated current is 500 mA, with overload and short circuit protection
function.
These terminals are provided to zone detectors.
These terminals are provided for telephone line connection.
TIP and RING are connected to external telephone line input.
TIP1 and RING1 are connected to housing telephone line.
The Connector is for RF receiver connection. +5V and GND provides a 5 VDC
power to WE 800 E RF receiver. RFIN is data in from WE 800 E RF receiver.
The Connector provides one programmable open collector output. The
maximum rated current is 100mA
The Connector is for tamper switch input.
Installation Manual