Bosch DS7200V2-UK Installer's Manual page 128

Table of Contents

Advertisement

Event as shown
Event #
in Panel Log
76
Fire,Cross
Fire Alarm
Cross Zone
77
Fire,Un-verified
Unverified
Event-Fire
78
Fire, Missing
Missing Fire
Trouble
79
Fire,Alrm,Rstl
Fire Alarm
Restore
80
Fire, Fault
Fire Trouble
81
Fire,Trbl,Rstl
Fire Trouble
Restore
82
Instl Mode,Start
Local Program LB
83
Instl Mode,End
Local
Programming
Ended
84
Log Overflow
Log Overflow
85
Log Threshold
Log Threshold JL
86
AltCom Low Signl
Low Received
Signal Strength
87
Missing,Alarm
Untyped
Missing Alarm
88
Missing, Fault
Untyped
Missing
Trouble
89
Open,Tmr
Automatic
Opening
90
Open, RPS
Remote
Opening
91
Open,Usr
Opening
Report
92
Open,KS
Opening
Keyswitch
93
Open,Tmr,Alarm
Disarm from
Alarm
Page 128
P/N: 4998152533-02
PART V: REFRENCE MATERIALS
SIA Report
SIA Report Data
ri {area} FM {loop}
ri {area} FG {loop}
ri {area} FY {loop}
ri {area} FH {loop}
ri {area} FT {loop}
ri {area} FJ {loop}
LX
JO
XL {device address} 350
ri {area} UZ {loop}
ri {area} UY {loop}
ai {252} OA {area}
ri {area} OQ {254}
ri {area} OP {user}
ss {255} OS {area}
ri {area} OR {252}
Table 47: Control Panel Events and Reporting Formats (continued)
Copyright  2007 Bosch Security Systems, Inc.
Contact ID Report
Event Description
110 Fire
Verified alarm event on fire
zone type with Cross Zone
Option. See Zone
Response Options on page
81.
378 Cross-zone
Unverified alarm event on
Trouble
fire zone type with Cross
Zone Option. Or unverified
event on Fire Verify zone
type..
373 Fire Trouble
Fire zone type assigned to
zone expander (wired or
RF) not responding to
panel's status poll.
110 Fire
Restoral from alarm, Fire
zone types
373 Fire Trouble
Fault (Trouble) condition on
Fire zone types
373 Fire Trouble
Restoral from Trouble, Fire
zone types.
466 Service On
Installer PIN entered.
Premises
Installer mode accessed.
466 Service Off
Installer mode exited.
Premises
624 Event Log
Panel log overflow
Overflow
condition. Oldest events
being overwritten.
623 Event Log
Panel log reached
threshold. See Log
Supervision Configuration
on page 50.
Low Signal Strength
Communication
detected on Alternate
Trouble
Communication device.
150 General Alarm Zone assigned to zone
expander (wired or RF) not
responding to panel's status
poll while system is armed.
382 Loss of
Zone assigned to zone
supervision
expander (wired or RF) not
responding to panel's status
poll while system is
disarmed.
403 Automatic O/C Opening by Sked (Timer).
400 Open/Close
Opening by RPS.
401 O/C by User
Opening by user, by ID
reported.
409 Keyswitch O/C Opening by Keyswitch.
403 Automatic O/C Opening after Alarm event
by Sked (Timer).
Zone Types
RPS
Status
Linked to
Event
Reports
Event
Group
1- Fire
2
1- Fire
5
2- Fire with
Alarm
Verification
1- Fire
5
2- Fire with
Alarm
Verification
1- Fire
7
2- Fire with
Alarm
Verification
1- Fire
5
2- Fire with
Alarm
Verification
1- Fire
7
2- Fire with
Alarm
Verification
11
R
11
R
12
R
12
R
12
R
8
3
10 - 15
3 - 8
6
10 - 15
10
10
10
10
DS7200V2-UK Installer's Guide