Bosch DS7200V2-UK Installer's Manual page 89

Table of Contents

Advertisement

Digit
Digit
Function Type
1
2
1
0
PO 2 (on-board) Siren
Supervision Fail
1
1
Sensor Trouble Monitor
1
2
Duress, [#][4][7] (reset)
resets.
1
3
User Tamper, [#][4][7]
(reset) resets.
1
4
Arming Beeps (for
keyswitch/RF arming)
1
5
Bell Time – Starts on
any Alarm Event. PIN
entry Stops. Activates
on Bell Test.
1
6
Strobe
1
7
Silent Alarm
1
8
Alarm – All On,
Perimeter Only, and
Partial On Arming, Non-
fire 24 hour alarms
1
9
Alarm – Perimeter Only
and Partial On Arming
Modes, Non-fire 24 hour
alarms
1
10
Alarm –Controlled
zones, 24-hr zones (Fire
and Non-Fire)
1
11
Fire Alarm
1
12
Fire Alarm, Latching
1
13
Fire Verification/Reset
1
14
System Trouble
1
15
[O] Key (Trapezoid Key
on RF Key Fob)
2
0
[P] Key (Rising Sun Key
on RF Fob)
2
1
'Panic' on RF Fob
DS7200V2-UK Installer's Guide
Output activates when a Siren Supervision Fail condition is detected. For Steady or Pulse modes, the
output remains activated until the condition is cleared and the [System Reset] key is pressed.
Output activates when a Sensor Trouble Monitor condition is detected in conjunction with the selection
made for the Sensor Monitor Time setting. For Steady or Pulse modes, the output remains activated
until the Sensor Monitor Trouble condition is cleared.
Output activates whenever a Duress PIN is entered. For Steady or Pulse modes, the output remains
activated until user presses [System Reset].
Output activates on a User Tamper event. For Steady or Pulse modes, the output remains activated
until user presses [System Reset].
Disarm/All On/Perimeter Only/Partial On Beeps for keyswitch/RF arming. 1=Off, 2=All, 3=Perimeter
Only. Mode and Time parameters do not apply. This function works in conjunction with Address
1039. See Global Output Options on page 84. Available for on-board outputs only .
Output activates on any alarm event. Entering PIN terminates Bell Time. For Steady and Pulse modes,
the output remains activated for the duration programmed in the Bell Time parameter.
PIN entry resets the function.
Activated by alarm on non-fire zones programmed for No Alarm Output. Follows Bell Time for Steady
and Pulse modes. PIN stops. The following conditions activate Silent Alarm:
Help Function Key programmed for Fire or Emergency and no Alarm Output
-
-
RF Keyfob programmed for Fire or Emergency and no Alarm Output
A zone programmed for Fire or Fire with Verify and no Alarm Output
-
-
Any zone not programmed for Invisible Panic that is programmed for no Alarm Output
Any armed zone programmed as a controlled type that goes from Supervised to Missing and
-
programmed for no Alarm Output
-
Any armed keyswitch programmed for no Alarm Output that goes from Supervised to Missing or
Short to Missing
-
Any zone programmed for Swinger Count and Swinger Count for Alarm Output that reaches its
programmed value
Activated by alarm on zone when All On, Perimeter Only, and Partial On Armed, or by alarm on Non-
fire 24 hour zone, and by user/installer 'Bell Test'. Follows Bell Time for Steady and Pulse modes. PIN
resets. Follows programming for 'Alarm' output types.
Activated by alarm on zone when Perimeter Only, and Partial On Armed, or by alarm on Non-fire 24
hour zone, and by user/installer 'Bell Test'. Follows bell time for Steady and Pulse modes. PIN resets.
Follows programming 'Alarm' output types .
Activated by alarm on zone when All On, Perimeter Only, and Partial On Armed, or by alarm on Fire
and Non-fire 24 hour zone, and by user/installer 'Bell Test'. Follows bell time for Steady and Pulse
modes. Pulses in Temporal Code 3 format for Fire alarms only. PIN resets.
Off-board outputs cannot provide output in Temporal Code 3 format (only on-board outputs).
Off-board outputs provide a steady output. Follows programming for 'Alarm' output types.
Temporal Code 3 for Fire alarms only .
Activated by alarm on Fire zone, and by user/installer 'Bell Test'. Follows Bell Time. Pulses in Temporal
Code 3 format. Mode and Time parameters do not apply. PIN resets.
Off-board outputs cannot provide output in Temporal Code 3 format (only on-board outputs).
Off-board outputs provide a steady output. Follows programming for 'Alarm' output types.
Activated by alarm on Fire zone, and by user/installer 'Bell Test'. Does not pulse in Temporal Code 3
format. Mode and Time parameters do not apply. [#][4][7] resets. Follows programming for 'Alarm'
output types.
Inverted, resettable output used with Fire Verification zones. Verification for Fire Verification Zone
Function type and [System Reset] activate output for approximately 15 seconds. Mode and Time
parameters do not apply. Used for 4-wire smoke detectors.
Activates on any System Trouble. Resets when all system troubles are clear.
Activates when Trapezoid Key on RF Keyfob is pressed. [System Reset] resets. Pressing O (trapezoid)
key again also resets output when Output Mode is set to Toggle. This output type is event-driven. See
Mode (Steady, Pulse, One Shot), Output ## on page 92 for more information.
Activates when Rising Sun Key on RF Keyfob is pressed. [System Reset] resets. Pressing P (sun) key
again also resets output when Output Mode is set to Toggle. This output type is event-driven. See
Mode (Steady, Pulse, One Shot), Output ## on page 92 for more information.
Activates when Arm Key (locked icon) and Disarm Key (unlocked icon) on RF Keyfob are pressed at
the same time, or when the [Q] button is pressed and it is set to Duress. See "[Q] Button Alarm
Response Options" in the DS7200V2 Expert Programming Guide (P/N: 4998153891). [#][4][7] resets.
Table 32: Output Function Types (continued)
Copyright  2007 Bosch Security Systems, Inc.
Description
P/N: 4998152533-02
PART IV: CONTROL PANEL PROGRAMMING
Page 89