5.12
System Error No. detailed list
No.
SYSTEM ERROR 03
SYSTEM ERROR 05
SYSTEM ERROR 06
SYSTEM ERROR 07
SYSTEM ERROR 08
SYSTEM ERROR 13
SYSTEM ERROR 20
SYSTEM ERROR 21
SYSTEM ERROR 30
SYSTEM ERROR 31
SYSTEM ERROR 32
SYSTEM ERROR 33
SYSTEM ERROR 34
SYSTEM ERROR 35
SYSTEM ERROR 36
SYSTEM ERROR 40
SYSTEM ERROR 41
SYSTEM ERROR 43
SYSTEM ERROR 50
SYSTEM ERROR 60
SYSTEM ERROR 61
SYSTEM ERROR 62
SYSTEM ERROR 63
SYSTEM ERROR 64
SYSTEM ERROR 65
SYSTEM ERROR 66
SYSTEM ERROR 67
SYSTEM ERROR 68
[Reproduction prohibited]
Error Detail
Setting save error
Software interruption
Undefined command
Pre-fetch abort
Data abort
Occur exceptionally other than
user's request reboot.
C/G1 error
C/G2 error
WLAN I/F(SDIO) initialization error
WLAN module initialization error
WLAN reception error
WLAN transmission error
WLAN I/F(UART) initialization

error

WLAN module F/W is not equipped
WLAN other error
Charging IC setting error
Battery wrong insertion error
Charge IC connection timeout
PLD version error
Engine error
Engine error
Engine error
Engine error
Engine error
Engine error
Engine error
Engine error
Engine error
Cause
The setting value failed to be saved in Flash
ROM.
It is possible to be displayed if program is
wrong.
It is running other than the program area, or
the program area is destroyed.
It accessed to an area without memory
implemented by command pre-fetch.
It accessed to an area without memory
implemented by data access.
It is possible to be displayed (for example, if
program is wrong).
ANK CG has not been downloaded.
Kanji has not been downloaded.
Interface initialization of the connection
portion (SDIO) with WLAN module is failed.
WLAN module doesn't respond. It failed in
parameter setting.
It failed to receive data from the module.
It failed to transmit data to the module.
Interface initialization of the connection
portion (UART) with WLAN module is failed.
SDIO can't initialize. WLAN F/W has not been
downloaded to the printer.
Illegal interrupt occurred on SDIO.
A command about charging IC has been sent,
but it was not received successfully.
Install high rate battery to B-FP3D-GS30/40
printer.
Timeout occurs at charge IC connection(I2C)
PLD version is less than V0.4.
PLD SPI data transmission (SET TXTXD data
- Motor Phase current Enable) failed
(time-out count 10000 times).
PLD SPI data transmission (Send Micro Step
Mode - Full command without continues data)
failed (time-out count 10000 times).
PLD SPI
DAC
(time-out count 10000 times).
PLD SPI data transmission (Send M-Enable
command with continues data) failed (time-out
count 10000 times).
PLD SPI data transmission (Micro Step Mode)
failed (time-out count 10000 times).
DAC output failed to retry-out.
There is an abnormality in LF Motor.
Command queue address error.
Command registration area is invalid.
-28-
data transmission failed