Restrictions on the ambient temperature

When using this product in an environment with a high ambient temperature, derate the product in accordance with the
following conditions:
120
100
80
60
40
20
0
0
10
20
Ambient temperature [°C]
120
HK-KT23UW/HK-KT43UW
100
80
60
40
20
0
0
10
20
Ambient temperature [°C]
*1 The HK-KT053W with an oil seal can be used at a derating rate of 80 %. When applying the derating in the conditions above, calculate
the multiplication of the derating rate of 80 % with an oil seal and the derating rate of each condition, and use the servo motor at the
calculated derating rate or lower.

Restrictions on the altitude

To use this product at an altitude between 1000 m and 2000 m, derate the product in accordance with the following conditions:
[%]
100
95
0
0
1000
Altitude
*1
HK-KT053W
/HK-KT13W
HK-KT1M3W
30
40
50
60
HK-KT103(4)W
HK-KT7M3(4)W
30
40
50
60
2000
[m]
120
100
80
60
HK-KT63(4)W
40
HK-KT23W/HK-KT43(4)W
20
0
0
10
20
30
Ambient temperature [°C]
120
HK-KT7M3UW/HK-KT103UW
100
80
60
HK-KT203(4)W
40
HK-KT153(4)W
20
0
0
10
20
30
Ambient temperature [°C]
6 HK-KT SERIES
HK-KT13UW
40
50
60
6
HK-KT202(4)W
40
50
60
119