2.
Select the menu Extender & Devices > EXT Units in the task area
and select the EXT Unit (CPU) with active USB-HID Ghosting.
Menu Extender & Devices - EXT Units
3.
Select the tab USB-HID Ghosting.
4.
Press the button Read. The current USB-HID Ghosting information of
the EXT Unit (CPU) is read out and shown. At the same time, the
USB-HID connection will be disconnected for a few seconds.
5.
Press the button Assign....
A popup window will appear.
6.
Select the those EXT Units (CPU) in the field Available to assign
settings to that are intended to receive the USB-HID Ghosting
information.
7.
Press the respective button to move the EXT Units (CPU) into the
field Assign settings to....
8.
Press the button Next >, confirm the occurring notification and finally
press Next > again.
9.
Press the button Start to activate the transmission and press the
Button Finish as soon as the transmission is completed.