4.
In order to configure the created extender as a CON Unit, set the
USB-CON (standalone) option to Y (C#1 in the Input Signals
column).
5.
Confirm the setting by pressing the Okay button.
6.
In order to configure the created extender as a CON Unit, set the
USB-CPU (standalone) option to Y (C#1 in the Output Signals
column).
7.
Confirm the setting by pressing the Okay button.
8.
In order to create an individually switchable Device for the USB 2.0
CON extender, select Configuration > CON Devices and press the
New R button.
Alternatively, you can assign the USB 2.0 CON extender to an
already existing CON Device. For this purpose, select the Device and
move the USB 2.0 CON extender from the EXT available field into
the EXT assigned field.
9.
Give an appropriate name to the new Device in the Name field.
10. Repeat the steps 8 and 9 for all USB 2.0 CPU extenders in the
Configuration > CPU Devices menu.
11. If you use parallel operation within the matrix, set the Release Time
in the Configuration > Switch menu to 10 s or more (see Chapter
5.13.6, Page 158).
12. Restart all I/O boards on which USB 2.0 extenders have been
configured or alternatively restart the matrix.
The USB 2.0 extender are now configured and can be used.