Ihse Draco tera 480 Series User Manual page 128

Kvm matrix switch
Hide thumbs Also See for Draco tera 480 Series:
Table of Contents

Advertisement

Draco tera
1.
Insert the SFP modules into the matrix and connect the extender
according to the required application.
One extender will be created for each SFP module in the Ext Units
list. The appropriate names always start with "UNI".
2.
In order to configure a CON Unit, select one of the extenders in the
Ext Units list that are physically connected to a USB CON Unit.
3.
Select the item UNI CON USB in the Type selection box of the
Extender Type tab and confirm your settings by pressing the Apply
button.
4.
Restart the I/O board upon request in the popup window by pressing
the Yes button.
5.
In order to configure a CPU Unit, select one of the extenders in the
Ext Units list that are physically connected to a USB CPU Unit.
6.
Select the item UNI CPU USB in the Type selection box of the
Extender Type tab and confirm your settings by pressing the Apply
button.
7.
Restart the I/O board upon request in the popup window by pressing
the Yes button.
8.
The edited EXT Units for the respecting USB CON Units now have to
be either assigned to an existing CON Device or you have to create a
new CON Device by using the New Device button for an assignment
in the Extender & Devices > CON Devices menu.
9.
The edited EXT Units for the respecting USB CPU Units now have to
be either assigned to an existing CPU Device or you have to create a
new CPU Device by using the New Device button for an assignment
in the Extender & Devices > CON Devices menu.
10. If you use parallel operation within the matrix, set the Release Time
in the System Settings > Switch menu to 10 s or more (see Chapter
5.13.6, Page 158).
The USB extenders are completely configured now and can be used.
Pos : 78 /806-IHSE/Konfig urati on/480_Konfig urati on v on SDI/Konfiguration v on SD I @ 15\m od_1433245237148_6.doc @ 161868 @ 2 @ 4
128
2020-02-26