Ihse Draco tera 480 Series User Manual page 127

Kvm matrix switch
Hide thumbs Also See for Draco tera 480 Series:
Table of Contents

Advertisement

6.
The edited EXT Units for the respecting USB CON Units now have to
be either assigned to an existing CON Device or you have to create a
new CON Device by using the New R. button for an assignment in the
Configuration > CON Devices menu.
7.
The edited EXT Units for the respecting USB CPU Units now have to
be either assigned to an existing CPU Device or you have to create a
new CPU Device by using the New R. button for an assignment in the
Configuration > CPU Devices menu.
8.
If you use parallel operation within the matrix, set the Release Time
in the Configuration > Switch menu to 10 s or more (see Chapter
5.13.6, Page 158).
9.
Restart the matrix.
The USB extenders are completely configured now and can be used.
Java-Tool
➔ Select Extender & Devices > EXT Units in the task area.
Menu Extender & Devices - EXT Units