➔ Select Configuration > EXT Units in the main menu.
Menu Configuration – EXT Units
1.
Insert the SFP modules into the matrix and connect the extenders
according to the required application.
One extender will be created for each SFP module in the EXT Units
list. The appropriate names always start with "UNI".
2.
In order to configure a CON Unit, select one of the extenders in the
EXT Units list that are physically connected to a USB CON Unit.
3.
Edit the extender by setting the USB-CON (standalone) option in the
Input Signals field to Y for C#1. Set additionally the Universal-CPU
option in the Output Signals field to N for C#1.
4.
In order to configure a CPU Unit, select one of the extenders in the
Ext Units list that are physically connected to a USB CPU Unit.
5.
Edit the extender by setting the USB-CPU (standalone) option in the
Output Signals field to Y for C#1. Set additionally the Universal-
CPU option in the Input Signals field to N for C#1.