8. Problems with mains operation of control unit
The KESSEL control unit detects faults during start-up and during operation, allowing them to be remedied easily.
8.1 Problems with mains operation / diode display
Fault display
Cause
Power-LED flashing,
Battery is missing or faulty
alarm-LED flashing
"Battery fault"
Acoustic signal
- Initialisation: "Motor" con-
Power-LED lit,
trol cable is not connected,
alarm-LED flashing
connected with inverse po-
quickly
larity or is broken
Flap-LED flashing
- During operation: "motor"
Acoustic signal
control cable faulty
"Motor fault"
- Initialisation: "Probe" con-
Power-LED lit,
trol cable is not connected,
alarm-LED flashing
connected with inverse po-
quickly
larity or is broken
Backwater-LED
- During operation: "Probe"
flashing
control cable faulty
Acoustic signal
"Probe faulty"
Flap cannot be closed com-
Power-LED lit
pletely during start-up or by
Alarm LED flashing
the "test" key, i.e. the flap is
Flap-LED flashing,
blocked by an object in the
Acoustic signal
backwater flap "Flap fault"
- Wrong lever position during
cover fitting
Backwater detected.
Power-LED lit,
The flap cannot be closed
Alarm-LED flashing,
completely, however, i.e. it is
Backwater-LED flas-
blocked by an object
hing
"Flap fault during backwa-
Flap-LED flashing,
ter"
acoustic signal
Max. number of cycles
Power-LED lit
Alarm LED flashing
for flap exceeded
alternating with flap-
LED
Power-LED lit
Motor transmitting figure
Alarm LED flashing
exceeded
at the same time as
Flap LED
Remedy
Remove the mains plug, connect
batteries, replace by new batteries
if necessary
When the unit is ready to function,
a running light appears on the dis-
play again.
Remove the mains plug, dis-
connect the battery; check the
control cable for correct connec-
tion or passage, replace motor if
necessary.
Remove the mains plug, dis-
connect the battery; check the
control cable for correct connec-
tion or passage, replace motor if
necessary.
Remove the mains plug, deactivate
the battery, open the Staufix cover,
eliminate the blockage and return
to operation
Recommendation:
Inform a specialist company
- See installation instructions 010-
842 (section 4.2.1)
Close the emergency valve. After
the end of backwater, remove the
blockage as describedn
Replace motor
Inform the customer servi-
ce partner
42
Notes
- Initialisation: The system can be put
into operation, i.e. it is functional.
Alarm can be acknowledged.
- Operation: The fault message ap-
pears after a maximum of 5 minutes.
The system is ready for operation, ma-
nual mode is possible.
Fault detection only takes place du-
ring operation (see chapter 8.2 "Ad-
ditional functions").
- Initialisation: Cannot be put into
operation
- During operation: Fault detection
during
manual
operation
cycle/backwater
The probe is scanned every 2 se-
conds.
Caution: Check position of the
operating valve! The control at-
tempts to close the flap 3 x in the
interval and perhaps eliminate the
blocking object in the process. If
the object can be removed by the
flap movement during these cy-
cles, the system is ready to be
used again. If this does not work,
the system switches to fault. Ack-
nowledgement of the acoustic sig-
nal is possible. It is also possible
to remove the object by flushing
the line. This can be checked by
pressing the test key again. In the
event of a negative result, the fault
message appears again; the ob-
ject must be removed as descri-
bed under remedial measures.
Motor service life reached
Flap closes too often within a
short time
test