7 Operation
7.4 Add liquid contents
Step
5
Finish the addition of liquids
To finish the addition of liquids follow the instructions below.
Step
1
232
Action
Re-install the side access door to 500 and 1000 L mixers. Follow the instruc-
tions below:
Using the handle, lift the door and align it with the side access
a
opening.
Turn the door clockwise to attach it.
b
Release the handle.
c
NOTICE
The side access door must be in place before the liquid
level rises above the lowest edge of the side access
opening.
Action
Continue filling the disposable bag with liquid. During filling, gently adjust
the bag position so that the bag shape fits the mixer vessel shape. Make
sure that the bag corners fit into the mixer vessel corners.