3 INSTALLATION and CONNECTION
4 Connect the pigtail cable.

3.4 Power supply connection

The power supply voltage to the camera is DC+12V. In
addition, the allowable range is DC11 to 17V.
Caution
Do not use an AC Adapter with output out of range. The
camera may have serious damage.
This product does not have a power switch. Be sure the
Power switch of AC Adapter is turned off before connecting
this product.
1
Confirm that the power supply switch of the AC
adapter is OFF.
2
Connect the DC cable to the DC OUT
connector of the AC adapter.
3
Connect the DC cable to the DC IN connector
on the camera.
4
Turn the power switch of the AC adapter to ON
to supply power to the camera.
(When the power is supplied, the camera STATUS
indicator turns Green on.)
Camera rear side
DC OUT
Connector
DC IN Connector
8
5 Secure it to the cable clamp.
AC Adapter
POWER
Switch
DC POWER Cable
UHL-43 2005 VER1 (E)
3.5 Connecting the
Remote Controller
Connect the LAN connector at the camera rear side and the
connector for LAN of the Remote control panel (OCP-300)
which can be controlled by the network connection via the
PoE+ (IEEE 802.3at)-supported network switch.
REMOTE option
CP Cable
LAN Cable
Network switch
(with PoE+)
Camera
AC Adapter
Note
The REMOTE (option) is necessary to use a conventional CP
cable.

3.6 Connecting a Monitor

Connect a monitor which has an HD-SDI input to the
MONITOR connector on the camera using a coaxial cable.
The output signal can be changed from the menu. The default
setting is 1080i59.94 format.
Coaxial
cable
Monitor
output

3.7 GENLOCK System

- - -
This section explains the input signal and output signal of the
GENLOCK system of this product.
Input synchronous signal
The output video signals can be locked to a standard
synchronization signal input to the GL IN/SYNC OUT
connector. The phase between the output video signals and
standard synchronization signal can be adjusted in horizontal
and vertical from the Menu.
Two types of signals can be input to the GL IN/SYNC OUT
connector:
- HDTV PS/S (tri-level sync)
- SDTV VBS/BBS (NTSC/PAL)
When switching between the input and output of the GL IN/
SYNC OUT connector and for phase adjustment of the output
video signal and the reference synchronous signal, refer to
"Chapter 5 Camera setting and adjustment".
Connecting of
COMMAND Connector
LAN Cable
OCP-300
Connecting to
LAN Connector
SDI Input
H LM905W C S H D