Bosch Rexroth IndraMotion MTX micro Easy Setup Manual page 154

For standard turning and milling machines
Hide thumbs Also See for Rexroth IndraMotion MTX micro:
Table of Contents

Advertisement

152/177
Bosch Rexroth AG
Block search in MTX micro
Overview of the System Data for the Block Pre-Run
Block pre-run data for axes "/
SysAxSRun"
Spindle block pre-run data "/
SysChSpSRun"
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
For more information, see the documentation "IndraMotion MTX Machine Pa‐
rameter", chapter "System data".
Structural element
Description
NotAdjusted
Axis not adjusted
PosNotAdjusted
Axis position not adjusted
ConfNotAdjusted
Channel assignment not adjusted
ReqPosAdjust
Position adjustment required
TargChan
Target channel
ReleaseChan
Release channel
Tab. 12-1:
Overview on the "SysAxSRun" structural elements
The system data structure "SysChSpSRun" is created for each channel in the
volatile memory.
The system data structure consists of three parts:
General data (SysChSpSRun):
Structure element
Description
MaxSpNumber
Highest spindle number available in the channel
PrgSpNumber
Highest programmed spindle number in pre-run
PrgCpNumber
Highest programmed coupling number in pre-run
ConstCutStatus
Adjust G-function group G96/97
SpeedStr
Speed syntax of a spindle
MoveStr
Movement syntax of a spindle
GearStr
Gear syntax of a spindle
SpConfNotAdjusted
Spindle configuration adjustment required
Tab. 12-2:
Overview on structure elements "SysChSpSRun" (general data)
Data channel spindles (SysChSpSRun.Sp[<channel spindle number>]):
Structure element
Description
SysSpNo
System spindle number
DriveNo
Drive number
IsProg
Spindle programmed in pre-run
NotAdjusted
Adjustment required
MoveNotAdj
Adjustment status of the movement function
GearNotAdj
Adjustment status of the gear
SpeedNotAdj
Adjustment status of the speed
LimitNotAdj
Adjustment status of the speed limitation
CcvNotAdj
Adjustment status of the G96 state
CAxisNotAdj
Adjustment status of c-axis required
OpModeNotAdj
Adjustment status of the drive operation mode
CpDataNotAdj
Adjustment status of the coupling data
DOK-MTXMIC-EASY*******-CO06-EN-P

Hide quick links:

Advertisement

Table of Contents
loading