DOK-MTXMIC-EASY*******-CO06-EN-P
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Each I/O device that is created has to be available in the device library.
Proceed as follows to create an I/O device:
Open the project in IWE
Switch the PLC offline
Drag&drop the I/O device from the library to the Sercos node
Switch the PLC online. The PLC with the changed configuration for
Sercos I/O devices is downloaded again
Connect the I/O device to MTX micro (X24 or X25) via Ethernet
Switch MTX micro off and on again. The address is assigned automati‐
cally after switching MTX micro on. Sporadically, MTX micro is started
multiple times
After the start-up, the I/O device is detected. Extend the PLC program to
contact the I/O addresses of the device
MTX micro automatically assigns Sercos addresses upon start-up.
Physically connect the I/O device in the same order they have
been created in IWE!
Query the status of the respective I/O devices via the Sercos I/O status dis‐
play.