Cu-Gh08 Control Unit Settings - DeDietrich AMC 15 Installation And Service Manual

Wall-hung gas condensing boilers
Table of Contents

Advertisement

Tab.60
On >
> Installation Setup > CU-GH08 > CIRCA ( Direct zone ) > Parameters, counters, signals > Parameters
Code
Text display
Zone friendly
Name
ZoneStartTimeHol
iday
ZoneEndTime
Holiday
ZoneEnd Change
Mode
CP000
MaxZoneTFlowSe
tpoint
CP010
Tflow setpoint
zone
CP020
Zone Function
CP060
RoomT. Holiday
CP070
MaxReducedRoo
mT.Lim
CP080
User T.Room
Activity
CP081
User T.Room
Activity
CP082
User T.Room
Activity
CP083
User T.Room
Activity
CP084
User T.Room
Activity
CP085
User T.Room
Activity
CP130
T.OutdoorToZone
CP200
Manu
ZoneRoomTempS
et
CP210
Zone HCZP
Comfort
CP220
Zone HCZP
Reduced
CP230
Zone Heating
Curve
7686707 - v.01 - 06092018
9.2.1
Description
Friendly Name of the user
zone
Zone Start Time holiday
Mode
Zone End Time of holiday
Mode
Zone End Time of change
Mode
Maximum Flow Temperature
setpoint zone
Zone flow temperature
setpoint, used when the
zone is set to a fixed flow
setpoint.
Functionality of the zone
Wished room zone
temperature on holiday
period
Max Room Temperature
limit of the circuit in reduced
mode, that allows switching
to comfort mode
Room setpoint temperature
of the user zone activity
Room setpoint temperature
of the user zone activity
Room setpoint temperature
of the user zone activity
Room setpoint temperature
of the user zone activity
Room setpoint temperature
of the user zone activity
Room setpoint temperature
of the user zone activity
Assigning the outdoor
sensor to zone ...
Manually setting the room
temperature setpoint of the
zone
Comfort footpoint of the
temperature of heat curve of
the circuit
Reduced footpoint of the
temperature of heat curve of
the circuit
Heating curve temperature
gradient of the zone

CU-GH08 control unit settings

Important
All tables show the factory setting for the parameters.
The tables also list parameters that are only applicable if the
boiler is combined with other equipment such as an outdoor
sensor or automatic refill device.
Adjustment range
0 °C - 90 °C
0 °C - 90 °C
0 = Disable
1 = Direct
5 °C - 20 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
5 °C - 30 °C
0 - 4
5 °C - 30 °C
15 °C - 90 °C
15 °C - 90 °C
0 - 4
10
15
25
25/28
MI
0
0
0
0
-
-
-
-
-
-
-
-
-
-
-
-
80
80
80
80
80
80
80
80
1
1
1
1
6
6
6
6
16
16
16
16
16
16
16
16
20
20
20
20
6
6
6
6
21
21
21
21
22
22
22
22
20
20
20
20
0
0
0
0
20
20
20
20
15
15
15
15
15
15
15
15
1.5
1.5
1.5
1.5
9 Settings
35
0
-
-
-
80
80
1
6
16
16
20
6
21
22
20
0
20
15
15
1.5
AMC
85