Safety and Responsibility

2 Safety and Responsibility

2.1 Intended Use, Incorrect Use and Misuse

Page 10 of 158
This section describes general considerations relating to user safety
that must be taken into account when working with the device.
In the remaining sections, warning notices are used only to highlight
particular hazards directly arising from the actions being described in
the section in question.
It is essential to read the operating manual carefully – espe-
cially this section and the warning notices in the text – and to
follow the instructions therein.
This section also refers to areas that are the responsibility of the pro-
vider due to certain risks arising from particular applications for which
the device is used deliberately and with full awareness of the associ-
ated risks.
Depending on its features, the device is designed to be used
as an incubation shaker for cultivating microorganisms or cell
cultures under the following conditions:
Cultivation of non-pathogenic microorganisms or cell
cultures of risk category 1 in a biotechnology labora-
tory of biological protection level 1.
Cultivation of pathogenic microorganisms or cell cul-
tures of risk category 2 in a biotechnology laboratory
of biological protection level 2.
When using the device in protection level 2, users are respon-
sible for taking appropriate protective measures to ensure
that organisms cannot escape uncontrollably due to flask
breakage, unintentional detaching of the sterile seal or simi-
lar.
WARNING
The device is designed and constructed exclusively for the intended
use described above.
Each instance of non-conventional use is considered as misuse and
may lead to dangerous situations.
20 August 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Multitron and is the answer not in the manual?

Questions and answers

Stephen Garcia
January 27, 2025

how to calibrate co2 on Model: Multitron Pro # I10102.1 and also purchase the solenoid valve # 52X06150GM

Srividya Murali
April 24, 2025

What is the meaning of Throw (fixed) and adjustable

1 comments:
Mr. Anderson
May 12, 2025

In the Infors HT Multitron, "adjustable throw" means the shaking motion can be changed by selecting one of four eccentric throw positions: 12.5 mm, 19 mm, 25 mm, or 50 mm. This allows customization of the shaking intensity for different applications. A "fixed throw" would mean the shaking motion is set to a single, unchangeable value. The Multitron supports adjustable throw, and only trained personnel are allowed to make changes to it.

This answer is automatically generated

Subscribe to Our Youtube Channel

Table of Contents

Save PDF