Set-Point Condition; Batching Operation; User Program Control Mode; Automatic Program Control Mode - CAS CI-6000A Series Manual

Table of Contents

Advertisement

6) Set-point Condition

Output is done according to the following condition in batching operation.
MODE
OUTPUT
COMMON
Zero band output
Optional preliminary
NORMAL
weight output
Optional preliminary
Loss – in
weight output
Preliminary
COMMON
weight output
Final weight
COMMON
Output
High limit weight
COMMON
Output
Low limit weight
COMMON
Output

7) Batching Operation

You can select batching operation method in set mode, F20.
a. USER PROGRAM CONTROL MODE
■ Normal Batching
■ Loss-in-Weight Batching
b. AUTOMATIC PROGRAM CONTROL MODE
■ Normal Batching
■ Loss-in-Weight Batching
CONDITION
GROSS weight ≤ Zero band
NET weight ≥ Final weight – Optional preliminary weight
GROSS weight > Optional preliminary weight
NET weight ≥ Final weight - Preliminary weight
NET weight ≥ Final weight - Free fall weight
NET weight > Final weight + High limit weight
NET weight < Final weight - Low limit weight