Writing(Command) & Response Format; Read The Set-Point Values From Ci-6000A With Pc; Command Format; Response Format - CAS CI-6000A Series Manual

Table of Contents

Advertisement

(D, ID : 00~99, CR:0x0d, LF:0x0a)
It is impossible to test with Print Key ( + Total Sum Print Key) ( Only possible when F35 = 0)
■ Format 1 [ Set Point Write :: COM1/COM2 Port available ]
Write the Set-Point values to the CI-6000A with PC
- Writing(Command) & Response Format
0
1
2
3
4
D
ID
H
A
17
18
19
20
21
Opt. Preli, Weight
34
35
36
37
38
,
Free Fall Weight
47
48
49
50
51
Lo Limit Weight
Note 1 : When you input the Set Point Value, you have to input without decimal point
■ Format 2 [ Set Point Read :: COM1/COM2 Port available ]

Read the Set-Point values from CI-6000A with PC

- Command Format

0
1
2
3
4
D
ID
H
T

- Response Format

0
1
2
3
4
D
ID
H
T
17
18
19
20
21
Opt. Preli, Weight
34
35
36
37
38
,
Free Fall Weight
47
48
49
50
51
Lo Limit Weight
Note 1 : All of Set Point Values are numeric without decimal point.
5
6
7
8
Set Point Code
22
23
24
25
,
Preliminary Weight
39
40
41
42
Hi Limit Weight
,
52
53
CR
LF
5
6
CR
LF
5
6
7
8
Set Point Code
22
23
24
25
,
Preliminary Weight
39
40
41
42
Hi Limit Weight
,
52
53
CR
LF
35
9
10
11
12
13
,
Zero Band
26
27
28
29
30
Final Weight
,
43
44
45
46
,
9
10
11
12
13
,
Zero Band
26
27
28
29
30
Final Weight
,
43
44
45
46
,
14
15
16
,
31
32
33
14
15
16
,
31
32
33