CAL 1

FUNCTION : Maximum Capacity Set (Range : 1 ~ 99,999)
KEY
:
Increase or decrease
of number
:
Shift of cursor position
ENTER :
Save and go to next
menu
Note 1. The maximum capacity means the maximum weight of the indicator.
Note 2. The max. weight is changed depending on the decimal point.

CAL 2

FUNCTION : Minimum Division Set (Range : 0.001 ~ 50)
KEY
:
Increase or decrease
of number
ENTER :
Save and go to next
menu
Note 1. The minimum division means the value of one division.
Note 2. The value of one division is changed depending on the decimal point.
Note 3. External resolution is obtained by dividing the maximum capacity into the min. division.
Set the resolution to be within 1/10,000.
If it is over 1/10,000, error message "Err 20" is displayed
DISPLAY
C = 05000
5000 kg
C = 0500.0
500.0 kg(First decimal point)
C = 050.00
50.00 kg (Second decimal point)
DISPLAY
d = 1
1 kg
d = 0.2
0.2 kg (First decimal point)
d = 0.05
0.05 kg (Second decimal point)
d = 0.001
0.001 kg (Third decimal point)