⑥ Options
F55
FUNCTION : Select of Option
DISPLAY
F55
Set value
( 0 , 2 )
F55
F55
F56
FUNCTION : Output Logic – BCD Out
DISPLAY
Set value
F56
( 0 , 1 )
F56
F57
FUNCTION : Analog Output Adjustment at Display Zero
DISPLAY
L 00000
Set value
( 0~4000 )
L 04000
L 04015
F58
FUNCTION : Analog Output Adjustment at Maximum Capacity
DISPLAY
H 10000
Set value
( 0~24000 )
H 20000
H 24000
0
Do not use
1
Analog Out(Option – 1,2)
2
BCD Out(Option – 3)
0
Positive Logic
1
Negative Logic
0mA,
0V
4.000mA, 2V
4.015mA, 2.007V
10mA,
4.16V
20.000mA, 8.33V
24.000mA, 10V