7. How To Install

1) Load cell connection

Connect load cell connector to load cell port which is in the backside CI-6000A
* Connecting method
Note 1.
In case of 4 wires L/C connect EX+ with SEN+, and connect EX- with SEN-.
Note 2.
Wire color can be different depending on the load cell's manufacturer or its model

2) Power

Adjusted to 220V 50/60Hz at factory.
(If you want to use 110V, adjust 110V/220V jump wire which is located
in the inner part of CI-6000A)
PIN
1 (EXC+)
2 (SEN+)
3 (EXC-)
4 (SEN-)
5 (SIG+)
6 (SIG-)
7 (SHIELD)