General
function
①
F01
FUNCTION : Decimal Point Adjustment
DISPLAY
F01
Set value
F01
( 0 ~ 3 )
F01
F01
F02
FUNCTION : Weighing Unit
DISPLAY
Set value
F02
( 0, 1 )
F02
F03
FUNCTION : A/D Conversion Speed
DISPLAY
F03
F03
Set value
( 0 ~ 9 )
F03
F03
F03
F04
FUNCTION : Digital filter
DISPLAY
F04
Set value
( 00 ~ 99 )
F04
F04
Note 1. Adjust the set value according to the condition.
0
No Decimal Point
1
1
10
2
2
10
3
3
10
0
Kilogram (kg)
1
Ton (t)
DESCRIPTION
0
20 times/sec.
1
40 times/sec.
2
60 times/sec.
3
80 times/sec.
4
100 times/sec.
10
10 time average value
50
50 times average value
99
99 times average value
27
DESCRIPTION
(ex : 12345)
(ex : 1234.5)
(ex : 123.45)
(ex : 12.345)
DESCRIPTION
DISPLAY
DESCRIPTION
F03
5
120 times/sec.
F03
6
140 times/sec.
F03
7
160 times/sec.
F03
8
180 times/sec.
F03
9
200 times/sec.
DESCRIPTION