5) How to input the set-point value

There are four ways to input the set-point value
■ First way (F50 = 0 )
To enter set-point, press the * key for 2 seconds in weighing mode
Note 1. Set F50 to 0 in set mode
Note 2. Shift the position of cursor with
go to next step, press the * key
STEP
STEP1
STEP2
STEP3
STEP4
STEP5
STEP6
STEP7
■ Second way (F50 = 0 )
Enter set value from F1 to F17 in set mode.
F11 : Zero Band
F12 : Optional Preliminary Weight
F13 : Preliminary Weight
F14 : Final Weight
F15 : Free Fall Weight
F16 : High Limit Weight
F17 : Low Limit Weight
■ Third way
Enter set-point by using RS-232, RS-485 Communication
Set F33 to 4 in set mode. Refer to set mode. (F33)
,
key and enter set value with
DISPLAY
Point
Zero Band
Shift the position of cursor with ,
ZEro bA
Enter Zero band value with
To go to next step, press the * key
1 - 00000
oP - Pre
Optional Preliminary
Input first weight
2 - 00000
PrELiM
Preliminary weight
Input Preliminary weight
3 - 00000
FinAL
Final weight
Input final weight
4 - 00000
FALL
Free Fall Weight
Input free fall weight
5 - 00000
H - LiMit
High Limit Weight
Input high limit weight
6 - 00000
L - LiMit
Low Limit Weight
Input low limit weight
7 - 00000