3.8 Change Timers
This function controls all timers of the Enforcer.
Timers
For a list of all timers, refer to Appendix C, on page 36.
Most commonly used timers:
Entry Time (0-255 seconds), Exit Time (0-255 seconds), Siren Time (2-15 minutes), Confirm
Time (1-99 minutes), Wireless Supervision Time (0-99 hours), App Exit Time (0-199
seconds)
NOTE: The timer for inputs on 'Soak Control' is in the function 'ENGINEER TESTS'.
Change Timers Programming
1. Press or to scroll to 'CHANGE TIMERS'. Press .
2. 'A Entry Time' will be displayed. Enter the time and press .
Refer to Appendix C, page 36 for all timers and enter the time
on the required function and press for the next timer.
3. Press to return to the Engineer menu.
3.9 Codes And Users
This function changes the Engineer code, the Master Manager code and adds/changes/deletes any
Duress or Guard codes.
Default Codes: User: None. Master Manager:2222. Engineer: 1111
NOTE: User codes, fobs and keyfobs can only be changed in The Master Manager Menu. Please see
the user manual for more information.
5 Digit Pins?
If enabled, all new codes added to the system will require a miniumum of 5 digits.
PLEASE NOTE: Any existing 4 digit codes will still be valid.
Delete Users And Fobs
This will delete all the key fobs and user codes from the system.
PLEASE NOTE: that this will not delete the Master Manager and the Engineer codes.
Change Duress Codes
[2] Duress Code: If the Enforcer is unset using a 'Duress' code, a silent 'Duress' or 'Hold Up'
signal is sent.
NOTE: ACPO policy prevents use of Duress codes for police call purposes.
[3] Guard Code: A 'Guard code' can be used to unset the Enforcer only after an alarm has been
activated for a minimum time (see 'Change Timer' Appendix C, page 36). The code will set a
system and an output type is available to signal when this code is used (0058 Guard Code).
[4] Dial Out: A dial code is used to force the panel to dial out the UDL software while in 'Day
Mode'
Change Master Manager Code
The Master Manager code can be 4, 5 or 6 digits long, or can be assigned to a tag. It may also
have the following functions:
[0] Unset / Set. [1] Unset Only. [2] Set Only. [3] None (used only to access the menu).
Flexi Set: If enabled, the default area the device is assigned to, will set. If disabled, the default
area will be shown on the display, and from here other areas can be selected.
Wards/Access: This will only be displayed if an Entry Control or Access Control reader is
installed on the system. If the address of the Entry Control or Access Control device is entered
here, then the code will be assigned to that reader only.
Change Engineer Code
The Engineer code can be 4, 5 or 6 digits long.
Enforcer: Programming Manual
Page: 16