Toshiba TLCS-900/L1 Series Manual page 150

Original cmos 16-bit microcontroller
Hide thumbs Also See for TLCS-900/L1 Series:
Table of Contents

Advertisement

Protocol
(1) Select 9-bit UART mode on the master and slave controllers.
(2) Set the SC0MOD0<WU> bit on each slave controller to 1 to enable data receiving.
(3) The master controller transmits one-frame data including the 8-bit select code
for the slave controllers. The MSB (Bit8) <TB8> is set to 1.
(4) Each slave controller receives the above frame. Each controller checks the above
select code against its own select code. The controller whose code matches clears
its WU bit to 0.
(5) The master controller transmits data to the specified slave controller whose
SC0MOD<WU> bit is cleared to 0. The MSB (Bit8) <TB8> is cleared to 0.
(6) The other slave controllers (whose <WU> bits remain at 1) ignore the received
data because their MSBs (Bit8 or <RB8>) are set to 0, disabling INTRX0
interrupts.
The slave controller (WU bit = 0) can transmit data to the master controller, and
it is possible to indicate the end of data receiving to the master controller by this
transmission.
Start
Bit0
1
2
3
Select code of slave controller
Start
Bit0
1
2
3
91C824-148
4
5
6
7
4
5
6
7
Data
TMP91C824
8
Stop
1
Bit8
Stop
0
2008-02-20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tmp91c824fgJtmp91c824-s

Table of Contents