7.
Drag the created end point to adjust the position.
Drag
The end point position also can be adjusted by changing the value of "End point" and "Digital value" in "Wave details setting".
Item
Description
Start point
The end point of the previous interval is displayed. To change the start point, change the end point of the previous interval.
End point
Set the number of data (position) for the destination end point. Note that the section No.1 cannot be changed because it is the first
point of the wave pattern.
Digital value
Set the digital value for the destination end point.
8.
Repeat steps 5 to 7 to create the wave to be output.
Each digital value of the created wave pattern can be checked by clicking the [Display Digital Value] button. Click the [Initialize
Graph] button to clear the created wave pattern contents. The graph and the contents of "Wave details setting" are cleared.
9.
Click the [Save Wave Pattern] button.
The saved wave pattern can be opened by clicking the [Open Wave Pattern] button.
10.
Set the save destination and the file name, then click the [Save] button.
11.
Click the [OK] button in the "Register wave pattern" window to register the created wave pattern.
12.
Repeat steps 3 to 11 to create other wave patterns.