Precautions

When configuring the offset/gain setting
Connect the engineering tool to the CPU module of the control system.
The engineering tool cannot recognize the D/A converter module if it is connected to the CPU module of the standby system.
Program examples
Unless otherwise specified, program examples provided in this manual and the following manual are for when the module is
used in the single CPU system or in the multiple CPU system.
 MELSEC iQ-R High Speed Digital-Analog Converter Module User's Manual (Startup)
When using the module in the redundant system, refer to the following manual and observe the precautions on programming
for when using the Process CPU (redundant mode).
 MELSEC iQ-R CPU Module User's Manual (Application)
Signal flow tracking setting
When using the module FBs and applying the program examples to an actual system, set "Signal Flow Memory Tracking
Setting" to "Transfer". If not, the module FBs and programs may not work properly when system switching occurs.
[CPU Parameter]  [Redundant System Settings]  [Tracking Setting]
APPX
200
Appendix 6 Using the Module in the Redundant System with Redundant Extension Base Unit